THE ULTIMATE OVERVIEW TO ESTABLISHING YOUR IP PA SYSTEM EFFECTIVELY

The Ultimate Overview to Establishing Your IP PA System Effectively

The Ultimate Overview to Establishing Your IP PA System Effectively

Blog Article

Network PA System for medium to large jobs



Introduction


The XC-9000 system is a completely electronic network PA system based on the TCP/IP method. By leveraging the TCP/IP procedure, the system guarantees the appropriate and reliable transmission of all information packets. Not just can it make use of existing computer networks, such as LANs or the Web, to transmit program signals, yet also it can additionally be released on a dedicated broadcasting network.


A single-server system can sustain up to 3000 terminals and enables for web server plunging. There are no limitations on the simultaneous broadcast channels, attaining true full electronic broadcasting.


System Characteristics.



Adaptable PA System Style


The PA system architecture is easy, including solution administration software program, network microphones, network amplifiers, network audio speakers, and various other devices.All tools is connected by means of the TCP/IP intranet method, permitting flexible arrangement and very easy management of the system, with complimentary control over broadcast web content, network devices, and areas with the network.


Comprehensive Sound Management


The audio administration software includes integrated functions for creating program plans, flexible zoning, and pre-scheduled broadcasts.It supports 24-hour programming, permitting altering settings during all the time


Versatile Audio Resource Assistance


The system sustains numerous types of audio resources for sending out alerts like real-time speech and BGM playback. Sound resources can originate from electronic musical apps, CD/DVD gamers, microphones, etc. On top of that, the system gives diverse features of supporting various broadcasting functions such as arranged broadcasting, zoned broadcasting, and emergency broadcasting.


Emergency Alarm System Assimilation


The system has an emergency alarm feature and can be incorporated right into a smoke alarm system. When the alarm main device gets the startling signals, the cord will send the signal to tools, which triggers the XC-9000, sending signals to audio speakers


Customers can choose to preset settings to turn on full-area or zoned alarm systems in emergencies. The alarm voices can be found in numerous kinds and can be modified accommodating needs. Customers can alter language settings, upload and edit their audio resources according to exact requirements, such as intruding alarms, fire alarms or air aid alarms, etc.


Fire Alarm System Combination


The system has an emergency alarm feature and can be incorporated right into a fire alarm system. When the alarm system main device obtains the startling signals, the wire will certainly transfer the signal to gadgets, which sets off the XC-9000, sending out signals to audio speakers


Individuals could select to pre-programmed settings to activate full-area or zoned alarm systems in emergency situations. The alarm system voices come in several kinds and might be modified satisfying demands. Customers can change language setups, upload and edit their audio sources according to precise requirements, such as intruding alarm systems, fire alarms or air aid alarms, etc.


App Control for System Operations


The system makes it possible for mobile application login and usage, enabling individuals to launch programs and other procedures to authorized terminals with the web server software, ensuring a practical and streamlined experience.


Integrated SIP Compatibility


The system not just allows SIP phones to visit, but additionally can be connected to third-party SIP server or IPPBX, which establishes a completely integrated and compatible interaction system with seamless combination right into existing systems.


Open SDK


When large job like clever park happens, the system offers an open SDK incorporated into third-party application systems


System Framework



Key Functions




Set up Playback


The system is able to automatically transmit according to the arranged jobs as long as customers publish the audio apply for each amount of time of the day to the server and create a playback timetable.


Area Broadcasting




The system can arbitrarily separate a couple of network devices right into different zones to play specified audio programs or send announcements to any type of assigned area. The volume of each gadget can be remotely changed.


Real-time Broadcasting


The system can relay and catch radio programs or other exterior audio sources in real-time, and at the very same time relayed them in sync.


Emergency Alarm Combination


The system can be incorporated with the fire alarm system for control. When a smoke alarm signal is triggered, it automatically turns on the emergency situation program function and supports adjacent flooring alarm systems. It additionally enables hands-on emergency broadcasting by clicking a solitary switch.


SIP Phone Combination


The system can be incorporated with SIP web servers, enabling real-time speech of voice broadcasting through SIP phones to send statements anytime and anywhere.


CCTV Combination


The electronic gadgets such as IP POE Audio speakers embraces the global common ONVIF procedure, which enables their voices to be broadcast using VMS platforms. The terminals can additionally be integrated with CCTV systems for integrated program.


Main Products.



Sound Administration Software XC-9000


B/S design, sustains cross-platform applications.
Covers traditional broadcasting system functions, permitting dividers management.
Unified management of terminals within the system, seeing work standing, and set quantity change, and so on.
Supports building multi-level web server architectures, releasing administration according to individual geographical regions.
Provides SDK advancement plans for second development and assimilation with various other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Show: 4-inch touchscreen, resolution 480 * 480.
Communication Methods: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Reaction: 100Hz~ 16KHz.
Operating Temperature: 0~ 45 ℃.
Measurements: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Show: 4-inch touchscreen, resolution 480 * 480.
Communication Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Regularity Reaction: 100Hz~ 16KHz.
Running Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Horn Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Communication Procedure: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Regularity Feedback: 100Hz~ 18KHz.
Intercom: Supported, Built-in Microphone.
Operating Temperature: -20~ 50 ℃.
Dimensions: 283.1 * 224.3 * 269mm.


Network Ceiling Audio Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Interaction Methods: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Regularity Response: 100Hz~ 18KHz.
Running Temperature level: -20 to 50 ° C.
Dimensions: φ213 x 165mm.


Network Wall Surface Mount Audio Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Interaction Method: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Regularity Reaction: 100Hz~ 18KHz.
Running Temperature: -20~ 50 ℃.
Measurements: 193x151.5 x292mm.


Network Column Speaker GEN-6191A03


Power Supply: DC24V/1A or POE.
Communication Method: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 90dB.
Regularity Action: 45Hz~ 18KHz.
Operating Temperature: -10~ 55 ℃.
Dimensions: 296x140x130mm.


Network Sound Bridge GEN-3101A01


Power Supply: POE.
Interaction Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 85dB.
Frequency Reaction: 50Hz~ 20KHz.
Running Temperature: -10~ 55 ℃.
Measurements: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Communication Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Regularity Response: 60Hz~ 18KHz.
Running Temperature: -10~ 50 ℃.
Dimensions: 440x300x44mm.


Zone Combining Digital Amplifier NBS-2301


Power Supply : AC 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Interaction Procedure : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Proportion :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Regularity Reaction :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Operating Temperature :.
10 ℃~ +50 ℃ (14 IP Paging Microphone ℉~ 122 ℉)
Dimensions : 483x430x88mm.


IP Interface System NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Communication Procedure: TCP/IP, UDP.
User interfaces: 1 Ethernet port, 32 alarm inputs, 8 alarm system outcomes.
Running Temperature level: -10~ 50 ℃.
Dimensions: 483x259x44mm.


Ip Pa SystemIp Paging System

Solution For Institution



Adaptable Zoning Program:


The totally network terminals can realize adaptable zoning alternatives, enabling broadcasting alerts to different areas or individual terminals ( devices).


College Bell System:


Ip Paging MicrophoneIp Paging System
It provides institution bell system at the beginning/ending of the course. Multiple scenarios can be developed, consisting of different arranged broadcast jobs according to summer/winter schedule.


Smoke Alarm Combination


It sustains assimilation with smoke alarm systems, enabling smoke alarm signals to be incorporated into the PA system.


Classroom Audio Boosting


Terminals sustain day-to-day applications in class scenes. They can be connected to projectors or interactive whiteboard for audio boosting.


Smart Street Lamp/Security Pole



Support SIP Procedure:


Integrated SIP method for smooth integration with network interaction systems.


VMS Platforms Assimilation:




Integrated ONVIF protocol for integration with VMS systems.


Third-Party Integration:


Developed in HTTP API for assimilation with 3rd party platforms.


Voice Alarm System Setting Off:


Developed in alarm system input interface for activating voice alarms with video cameras.


Option For Resort



Area Control by Flooring:


The system uses complete network setups, splitting zones counting on different floorings and control over each area separately.


Fire Alarm Assimilation:


The system can be integrated with smoke alarm system, making it possible for combination of smoke alarm signals right into the broadcasting system.


Scheduled Broadcasting:


It supports programmable scheduled broadcasting, enabling flexible setups according to various needs.


Emergency Broadcasting:


It supports emergency situation broadcasting for the whole location, allowing one-click emergency interaction. - IP Paging System


Ip Pa SystemIp Speaker

Option For Factory



Area Broadcasting:


It allows broadcasting to any kind of area, ensuring no disturbance between various locations.


Alarm Triggering:


Terminals have numerous kinds of interfaces, allowing to cause alarm systems when gotten in touch with cameras.


All Network Devices:


Deployment of fully network tools significantly reduces the trouble of running such as examining tools on unsafe websites, and thus protecting people and property.


The deployment of all network devices greatly decreases the trouble of procedure and maintenance management


Integrated SIP Phones:


The system can be incorporated with SIP phone and broadcast notifications utilizing SIP phones any time and anywhere. Two-way audio talkback between SIP phones and IP POE Speakers makes it easy for examining gadgets being in office or other workplaces.


The XC-9000 system is a fully electronic network PA system based on the TCP/IP protocol. By leveraging the TCP/IP procedure, the system makes certain the appropriate and effective transmission of all information packages. The system supports numerous types of audio resources for sending out alerts like online speech and BGM playback. In addition, the system supplies diverse features of sustaining different broadcasting features such as set up broadcasting, zoned broadcasting, and emergency broadcasting.


The system can be incorporated with the fire alarm system for control.